Found in the Polymer module, on the Properties tab.
Builds an amorphous cell of a neutral polymer and computes, by molecular dynamics:
its density;
its free volume;
its chain dimensions;
optionally its glass transition temperature and thermal expansion.
Input¶
Repeat unit. Give the monomer as SMILES and press ◎ Show & pick, or press
📂 Structure file. Any structure format the app reads works. Then click the two atoms
where the chain continues, as in the Ion conductivity tab. For
polystyrene, enter C=Cc1ccccc1 and click the two vinyl carbons. The result appears as
*CC(*)c1ccccc1, and you can also type a *-marked SMILES directly.
Copolymers. Choose the Type:
| Type | Sequence |
|---|---|
| Homopolymer | A only |
| Random copolymer | A and B in random order, with the fraction of A you give |
| Alternating copolymer | ABAB… |
| Block copolymer | A…AB…B |
A second repeat unit, B, appears for the copolymer types. Every chain in the cell has the same sequence.
Charged polymers. A repeat unit with a charge in its SMILES, such as
*CC(*)c1ccc(C[N+](C)(C)C)cc1 or *CC(*)c1ccc(cc1)S(=O)(=O)[O-], gets one counter-ion
per charge. Choose it under Counter-ion:
for a cationic polymer: Cl⁻, Br⁻, OH⁻, HCO₃⁻, TFSI⁻ or FSI⁻;
for an anionic polymer: Li⁺, Na⁺ or K⁺.
By default Cl⁻ or Na⁺ is used. The cell is dry. For a hydrated membrane, and for ion transport, use the Ion conductivity tab.
Additives. Up to three neutral molecules, such as plasticisers, each given as a SMILES and a weight percent of the whole cell, at most 60 wt% in all.
They get the same standard force field as the polymer.
They are packed in between the grown chains before equilibration.
The result lists how many molecules were placed and the weight percent that gives. It is rounded to whole molecules, so use a larger cell for low contents.
A Tg scan with and without a plasticiser shows the shift it causes.
| Setting | Default | Meaning |
|---|---|---|
| Units per chain | 20 | |
| Chains | 6 | the cell must be at least ~1.6 nm across when fully compressed, so very small cells are refused |
| Temperature | 298.15 K | for density, free volume and chain size |
| Production | 2 ns | NPT run the properties are taken from |
| Pressure | 1 bar | Advanced |
| Random seed | 0 | chain growth and the random sequence, Advanced |
How the cell is made¶
Force field. Each repeat unit gets the app’s standard force field and charges. Nothing is fitted to the monomer, so this takes seconds.
Chains. Chains are grown as random coils inside the periodic cell at 0.5 g/cm³, so they interpenetrate as in a melt. They are not packed as extended rods.
Equilibration. The 21-step compression/decompression protocol of Larsen et al. (2011) brings the cell to its density: 600 K and 50 kbar, then back to the target conditions, 1.56 ns in all.
Production. An NPT production run follows.
Results¶
Density: the mean and standard deviation over the second half of production.
Fractional free volume (FFV): Bondi’s definition, (V − 1.3 VvdW)/V. Every atom in the cell counts, including counter-ions and additives. Ions are given Bondi’s atomic radii, which are larger than their ionic radii, so the FFV of an ion-containing cell is somewhat underestimated.
VvdW is the volume of the union of the atoms’ Bondi spheres, measured on a 0.5 Å grid over the cell, averaged over the last 20 frames.
Glassy polymers are typically 0.11–0.20; polymers of intrinsic microporosity reach about 0.25.
Volume open to a gas molecule: the share of the cell where the centre of a He, H₂, CO₂, O₂, N₂ or CH₄ molecule (kinetic radius) can sit without overlapping an atom. It is much smaller than the FFV by construction. Use it to compare how open different polymers are to each gas.
Chain dimensions: radius of gyration, end-to-end distance, and their ratio ⟨R²⟩/⟨Rg²⟩, which is 6 for an ideal coil.
A trajectory movie of production, with the same three periodic views as the Ion conductivity tab.
Glass transition and thermal expansion¶
Tick Tg and thermal expansion. After production the cell is heated to the From temperature, held there for two steps’ worth of time, and cooled in steps (Step, ns per step) down to To. The density at each temperature is the mean over the second half of its step.
Tg is where two straight lines fitted to density against temperature meet. The break point is scanned, and its uncertainty comes from refitting resampled data. If one straight line fits almost as well as two, the result says there is no clear break: widen the range or cool more slowly.
Thermal expansion is reported for the glass and the melt: the volumetric coefficient −(1/ρ) dρ/dT at Tg, and, for an isotropic solid, the linear coefficient, about a third of it.
The temperatures and densities are written to
density_vs_T.csvin the run folder.
The sidebar shows how many temperatures and how much MD the scan needs. The default, 550 → 250 K in 20 K steps of 1 ns, is 16 temperatures and 18 ns: a few hours on a GPU for the default cell.