Predicts the properties of a pure liquid from its SMILES or XYZ coordinates, by molecular dynamics with a force field refined for that molecule.
Properties¶
| Property | Unit | Notes |
|---|---|---|
| dynamic viscosity η | mPa·s (cP) | |
| kinematic viscosity ν | mm²/s | |
| density ρ | g/mL | |
| enthalpy of vaporisation ΔHvap | kJ/mol | |
| dielectric constant ε | a lower bound unless you give the refractive index (below) | |
| vapour pressure pvap | Pa | needs a known point on the curve, or the FEP |
| boiling point Tb | K | likewise |
| residual entropy Sres | J/(mol·K) | from the FEP only |
The self-diffusion coefficient and the radius of gyration are in the calculation log. No flash point is given: the correlation tested was about 100 K off against handbook values, so no number is reported rather than a wrong one.
Pipeline¶
A 3D structure (from the SMILES, or the XYZ coordinates as given) and an initial GAFF force field are generated.
Gas-phase conformers are sampled.
The charges, non-bonded parameters and dihedrals are refined against quantum chemistry, to the depth set by the QM preset. With Quick charges, only the charges are refined. A refined force field is saved and reused for the same molecule and preset (untick Reuse saved force field to refine again).
A liquid box is built, equilibrated, and simulated.
The self-diffusion coefficient comes from the mean-squared displacement, with a finite-size correction, and the viscosity from the Stokes–Einstein relation.
ΔHvap is the liquid’s energy per molecule against one molecule in the gas phase, both with the same force field.
ε comes from the fluctuations of the box dipole. Because it converges much more slowly than the other properties, this sampling continues on its own until ε stops changing, up to Dielectric: extend up to (default 10 ns; 0 uses only the production run).
Settings¶
| Setting | Default | Notes |
|---|---|---|
| Input | SMILES | SMILES, or XYZ coordinates (paste them or load an .xyz file; Å) |
| Temperature | 298.15 K | |
| Pressure | 1.013 bar | |
| Platform | CPU | choose OpenCL or CUDA if you have a GPU: much faster |
| QM preset | Fast | Fast, Standard, Accurate: how thoroughly the force field is refined |
| Charges | Quick | Quick: refines the charges only; much faster, and the charges stay close to the fully refined ones (about 0.01 e). Refined: the full refinement |
| Equilibration | 0.2 ns | |
| Production | 1.0 ns | longer runs give smaller statistical error |
Optional inputs:
Measured pvap at a temperature, or a known boiling point. ΔHvap fixes how steeply the vapour pressure changes with temperature, not its absolute value. One known point fixes that, and the vapour pressure then comes out at no extra cost, within about 10 % of experiment.
Fit to experiment: the measured density and ΔHvap at the run temperature. With both given, the force field’s size and cohesion are fitted to them before the MD (about an hour, reused on later runs with the same values).
Refractive index n: fixed charges have no electronic polarisation, so ε is a lower bound. Giving n adds the electronic term n² − 1.
↻ Update results with these values recomputes vapour pressure, boiling point and ε from the last result with new optional inputs, without a new simulation.
Vapour pressure without data¶
Tick Vapour pressure & boiling point (off by default) to run a free-energy perturbation of the molecule solvated in itself, at the density from the MD. This gives a vapour pressure for a compound with no measured data; the boiling points that follow were within 1.6 K on average of experiment for the liquids tested. FEP length per λ window sets the cost: Fast 200 ps, Standard 500 ps (default), Accurate 1 ns. It takes hours, so if you know the boiling point, give it above instead.
With the COSMO-RS add-on¶
Mutual solubility with water¶
When the COSMO-RS add-on is licensed, every run of a neutral molecule also reports how much of the liquid dissolves in water and how much water dissolves in the liquid, at the run temperature, in % w/w (or miscible). It takes seconds. Water in the liquid is usually close: for 1-octanol, 5.0 % against 4.9 % measured. A small solubility in water can be several times too high: for 1-octanol, 0.25 % against 0.054 % measured.
Binary mixture¶
The Binary mixture button at the top of the sidebar switches to the vapour–liquid equilibrium of two liquids:
Components: a solvent from the list or any neutral SMILES. Each needs a boiling point and an enthalpy of vaporisation, which set its vapour pressure through Clausius–Clapeyron. Use measured values, or Use the last pure-liquid result to take them from a run in the Pure liquid tab. That fills the computed ΔHvap and the boiling point, if the run produced one.
Diagram: T–x–y at a fixed pressure (1 atm by default) or P–x–y at a fixed temperature.
The result shows the bubble (liquid) and dew (vapour) curves, any azeotrope and whether it is minimum- or maximum-boiling, and the excess Gibbs energy GE across the composition (at 25 °C for a T–x–y diagram). If some compositions would separate into two liquids at their boiling temperature, those points are drawn hollow and flagged, because there the mixture boils as two liquid phases.
The activity coefficients come from COSMO-RS. The vapour pressures do not, because COSMO-RS’s own pure-liquid vapour pressures can be off by orders of magnitude. The vapour is treated as ideal.
| Mixture at 1 atm | Computed azeotrope | Measured |
|---|---|---|
| chloroform / acetone | maximum-boiling, x = 0.67, 63.8 °C | x ≈ 0.65, 64.5 °C |
| ethanol / water | minimum-boiling, x = 0.97, 78.2 °C | x ≈ 0.89, 78.2 °C |
| methanol / water | none | none |
The azeotrope temperature is reliable. Its composition is sensitive when the two boiling points are close and the azeotrope is shallow, as with ethanol and water.