Skip to article frontmatterSkip to article content
Site not loading correctly?

This may be due to an incorrect BASE_URL configuration. See the MyST Documentation for reference.

How strongly do two molecules bind? Enter both molecules and press ▶ Run. The module finds the most stable way the two molecules fit together and reports the binding energy.

Each molecule is given as a SMILES or as a structure. Open file… reads XYZ, Molfile/SDF, MOL2, PDB, CDXML, and the inputs and outputs of the common quantum-chemistry programs; a file with several structures asks which one to use. A structure overrides the SMILES. Set the charge yourself if it is not zero.

What it does

  1. Each molecule on its own: a conformer search, then the lowest few conformers are re-optimised and the best one is kept.

  2. The two together: molecular dynamics of the pair, with snapshots minimised, finds the ways the two molecules can sit against each other. The lowest few complexes are re-optimised, and duplicates are removed.

  3. Energies: single points at the chosen level on the best monomers, on every complex, and on each monomer frozen in the shape it has inside each complex.

What it reports

QuantityDefinition
Binding energy (headline)E(AB) − E(A) − E(B), each molecule at its own best structure
Interaction energyE(AB) − E(A) − E(B) with the monomers frozen as in the complex
Deformation energythe cost of distorting each monomer into its shape in the complex. Binding = interaction + deformation
Boltzmann-averaged bindingthe binding energy averaged over the complexes found, weighted by their populations

A negative binding energy means the complex is stable. Energies are in kJ/mol and kcal/mol.

The complexes are listed with their relative energies and populations. Click one to see it in 3D: molecule A has grey carbons, molecule B cyan.

Levels

LevelStructuresEnergiesTypical time (small molecules)
GFN2-xTB throughoutGFN2-xTBGFN2-xTBabout a minute
r²SCAN-3c, xTB structures (default)GFN2-xTBr²SCAN-3ca few minutes
r²SCAN-3c, r²SCAN-3c structuresr²SCAN-3c, after an xTB pre-optimisationr²SCAN-3clonger
CustomxTB, AIMNet2 or DFTxTB or any listed functional and basis

r²SCAN-3c is Grimme’s composite method: the r²SCAN functional with the def2-mTZVPP basis, its own D4 parameters and a geometric counterpoise correction (gCP). It was designed for structures and non-covalent interactions at modest cost.

Solvation (CPCM, SMD or COSMO-RS) applies to the energies. When a DFT optimisation runs in a solvent, it uses CPCM, because VeloxChem has no SMD or COSMO-RS gradients. COSMO-RS needs neutral monomers and complexes.

RI speeds up the DFT energies. One choice holds for the whole run, so the complex and its monomers are always computed the same way. Before you start, the module estimates the memory RI needs for the pair and warns when it does not fit in the free memory (less a reserve for other programs). The run then computes every energy without RI, which is slower but keeps the energies comparable. A pair of around 200 atoms with r²SCAN-3c needs about 34 GB.

Under Advanced you can set how many conformers of each molecule and how many complexes are refined (default 3 and 5), and the temperature for the Boltzmann average.

Limitations

Results are recorded for Previous, and the module works with Save/Load and the job queue.